The complete R454B Infinity Series and Hybrid Heat class taught by Pat Burke on 5/1/2025.
Infinity Basic covers essential aspects of HVAC design and installation, focusing on system components, proper zoning, and dual fuel setups. It highlights the importance of accurate refrigerant charging, thermostat settings, and airflow adjustments. The session also addresses common installation issues, the significance of wiring connections, and the impact of duct layout on system efficiency. Key updates on equipment and troubleshooting methods are discussed to enhance user comfort and operational effectiveness.
00:00 – Intro & Class Updates
03:07 – Installation & Infinity System
04:27 – Comfort & Zoning Systems
08:14 – Product Info Access
36:47 – Software Updates & Devices
41:55 – Wiring & Outdoor Units
47:19 – Heat Pump Mechanics
01:15:50 – Thermostats & Airflow
01:21:36 – Safety & System Alerts
01:51:44 – Zoning & Dampers
02:00:39 – Wiring & Connections
02:28:48 – Airflow & Machine Capacity
02:43:03 – Refrigerants & Sensors
02:48:24 – Connectivity Troubleshooting