ULN SPP Sales, Design & Install

This comprehensive class covers Ultra Low NOx (ULN) regulations and Carrier HVAC product installation and service. Learn about NOx reduction strategies, unit nomenclature, product data, and essential installation practices like Manual J and Manual D. The video details critical aspects of gas piping, electrical connections, and precise gas manifold pressure settings for optimal performance and compliance.

00:00 – ULN Class Intro & Regulations
08:06 – ULN Unit Specs & Design
31:52 – Installation, Ductwork & Airflow
47:57 – Sales, Pre-Installation & Rigging
01:08:07 – Gas & Electrical Setup
01:18:29 – Gas Pressure Setup & Tools
01:33:54 – Air Temperature & Blower Speed
01:38:39 – Burner & Heat Exchanger System
01:50:12 – Inducer Motor & Pressure Switches
02:03:09 – Advanced Troubleshooting & Diagnostics
02:23:36 – Noise Reduction & Final Checks